Home Page
  Vehicles  Winches  -   Sensors  - FerryBox  .   Sonar T & E Systems   .   Telemetry   .  Hydrophones   .  Projectors   .  Custom Design   .   Deck Units  .   Military Capabilities   .  Homeland Security  -    Equipment Rental   .  Pipeline Leak Detection System     .  Calibration Facility   .  Representatives Details   .   News  .  Jobs  .   Brochures  . Facts Sheets  .  Technical Papers  . Company Background  .   Location Map  .   Enquiry Form    



.


Breaking News: MINItracka now available as a UV fluorimeter

 click below   

Applications Product Description Datesheet (pdf)
Features Specification 

Dye Tracing Case Studies (pdf)


Applications

Features

In-situ hydrocarbon detection / monitoring  
Water mass indicator studies (Gelbstoff)
Pipeline leak detection
Pollution monitoring
Designed for use on profiling, towed,
moored or ROV deployments
Biogeochemical oceanography

 
.. 
..


..

.

Small, low cost fluorimeter
Robust miniature Optics
High sensitivity
Low turbidity breakthrough
Ground loop isolation to facilitate system integration
Acetal Housing for corrosion inhibition
Low power consumption
Analogue output
High rejection of ambient daylight

Stable zero with low temperature coefficient
Very low noise & large dynamic range with ultra-linear signal processing
Accepts 6 : 1 supply voltage input

(top)

Product Description

The UV MINItracka is a submersible fluorimeter to monitor the concentration of hydrocarbons (360nm) or Gelbstoff (440nm) in a wide range of oceano- graphic applications. In support of this, it has been designed to be deployed from submersible vehicles, moored or profiling systems. This robust, compact, lightweight instrument provides significant improvements in power consumption over its predecessor, the UV AQUAtracka. The instrument is easy to use and gives accurate and repeatable measurements.

The UV MINItracka's pressure housing is manufactured in acetal for long life. It utilizes a high power LED light source and a low temperature coefficient photodiode which feeds a low noise preamp that, together with phase sensitive detection, gives an overall electronic noise figure close to the theoretical minimum possible. Data output is factory set as linear analogue.   The performance of  MINItracka II has a high degree of insensitivity to water temperature changes due to the low tempco of the new generation SQW LEDs, the selected photodiode used and the careful circuit design.

(continue reading description - next column)
.

The sophisticated design of the electronic signal processing, combined with cowl design principles of its predecessor, the UV AQUAtracka incorporated in the pressure housing, enables it to operate successfully in high levels of ambient light. Hence, using UV MINItracka means there is generally no requirement to pump seawater through a dark observing chamber, thus obviating the need for water flow corrections - not to mention the cost, inconvenience and power drain of a pump. For deck & laboratory applications, a flow through manifold is available.

The ease of use and installation is further enhanced by the provision of galvanic isolation between the power
0 volt and signal 0 volt lines within UV MINItracka, thereby interrupting possible 'ground loops'. The high efficiency, proprietary design DC converter can also handle the unusually wide range of supply voltages between 7V and 40V without significant change in a power drain of 0.7W. The output will drive almost any sort of measuring or data logging device. It should be noted that the output of UV MINItracka II is linearly related to concentration and not logarithmically as might be expected from its UV AQUAtracka origins. 
 

Specification

  Physical  

Size:

70mm dia x 149 mm

Weight in air:

0.7kg

Weight in water:

0.15kg

Pressure housing:

Acetal

Depth rating:

600 metres

Connector:

Subcon MCBH4M

  Optical    

 

HYDROCARBON (360nm)

GELBSTOFF (440nm)

 

Excitation

Emission

Excitation

Emission 

Peak Wavelength:

250nm

360nm

250nm

430nm

 Performance  

 

HYDROCARBON (360nm)

GELBSTOFF (440nm)

Range: 

0 to 10mg/l Carbazole

0 to 10mg/l Perylene

Resolution: 

0.01 mg/l Carbazole
or 1% of reading

0.01 mg/l Perylene
or 1% of reading

 Environmental  

Operating Temperature:

 -2 deg C to +40 deg C

Storage Temperature:

-40 deg C to +70 deg C

Note: The UV MINItracka is provided with a 3 foot pigtail, locking sleeve Handbook and Calibration Certificate.
Options: Deck units, calibration equipment.

All instruments & support systems can be supplied by Chelsea Technologies Group Ltd

In view of our continual improvement, the designs and specifications of our products may vary from those described.


Chelsea Technologies Group Ltd
55 Central Avenue, West Molesey,
Surrey, KT8 2QZ, UK.
Tel: +44 (0)20 8481 9000    Fax: +44 (0)20 8941 9319
Email: sales@chelsea.co.uk